F51 vs F60: differences between S31803 and S32205

F51 and F60 are the same duplex 2205 in two composition ranges. F60 (UNS S32205) requires higher minimum chromium, molybdenum and nitrogen than F51 (S31803), which guarantees a higher minimum PREN, and it has a higher minimum tensile strength in ASTM A182. S32205 material also meets S31803, so most of it is sold dual certified F51/F60.

F51 vs F60
PropertyDuplex 2205 (F51 / S31803)Duplex S32205 / F60
Identification
GroupDuplexDuplex
UNSS31803S32205
W.Nr. / EN1.44621.4462
Chemical composition (%)
C≤ 0.030≤ 0.030
Mn≤ 2.00≤ 2.00
Si≤ 1.00≤ 1.00
P≤ 0.030≤ 0.030
S≤ 0.020≤ 0.020
Cr21.0–23.022.0–23.0
Ni4.5–6.54.5–6.5
Mo2.5–3.53.0–3.5
N0.08–0.200.14–0.20
Composition: standardUNS S31803 (A240, A182 F51, A790)UNS S32205 (A240, A182 F60, A790)
Mechanical properties (minimum)
Yield strength––
Tensile strength––
Elongation––
Hardness––
Properties: conditionA182 F51 (S31803), solution annealedA182 F60 (S32205), solution annealed
Use and supply
PREN (minimum – typical)31 – 3434 – 36
Density7.8 g/cm³7.8 g/cm³
Service temperature––
Standards by product formPlate, coil, strip: A240 / SA-240
Bar and section: A276; A479 / SA-479
Forging and flange: A182 / SA-182
HIP part (powder metallurgy): A988 / SA-988
Seamless and welded pipe (piping): A790 / SA-790
Plate, coil, strip: A240 / SA-240
Bar and section: A276; A479 / SA-479
Forging and flange: A182 / SA-182
HIP part (powder metallurgy): A988 / SA-988
Seamless and welded pipe (piping): A790 / SA-790
Typical applicationsOffshore oil and gas
Chemicals and petrochemicals
Pulp and paper
Chemical tankers
Offshore oil and gas
Chemicals and petrochemicals
Pulp and paper
Chemical tankers

Composition and minimum properties per the standard listed on each datasheet; PREN uses the minimum and the middle of the ranges. For the actual value, use the heat certificate.

Quote these materials

Most searched comparisons

For pitting resistance, see the PREN calculator; for steel weldability, the carbon equivalent; to choose by medium, steel by corrosive medium.

Frequently asked questions

Can F60 be used where F51 is specified?

Yes. The S32205 range fits inside the S31803 range, so an F60 heat meets F51. The opposite only holds if the heat also meets the S32205 minimums.

What is F51/F60 dual certification?

It is a certificate stating that the heat conforms to both designations, because its composition and properties meet both at the same time.

Which one should I ask for in a quote?

Ask for what the project requires. If the drawing says F51, an F51/F60 part works; if it says F60, the certificate must show S32205.

HelenaVirtual assistant · WhatsApp

Request a quote

Subject: . Fill in and send: your request goes to our technical team and we reply by email.

More details (optional): tax ID, delivery, deadline and requirements
Requirements

Drawing, list or specification. Up to 5 files and 15 MB in total.

Send via WhatsApp

We use your data only to answer this quote. Privacy. · WhatsApp +55 11 98649-0075 · Mon–Thu 07:00–17:00 · Fri 07:00–16:00 (Brasília time)