Duplex 2205 vs super duplex 2507: differences and selection
2507 (UNS S32750, F53) is the super duplex: about 25 % chromium, 3.0–5.0 % molybdenum (typically ≈ 4 %) and more nitrogen than 2205 (S31803/S32205, F51/F60). PREN is 40 or higher (the value required in purchase specs), against 31–34 for 2205, and minimum yield rises from 450 to 550 MPa. Use 2507 in seawater and hot chlorides; 2205 handles moderate chlorides at lower cost.
| Property | Duplex 2205 (F51 / S31803) | Super duplex 2507 / F53 / S32750 |
|---|---|---|
| Identification | ||
| Group | Duplex | Duplex |
| UNS | S31803 | S32750 |
| W.Nr. / EN | 1.4462 | 1.4410 |
| Chemical composition (%) | ||
| C | ≤ 0.030 | ≤ 0.030 |
| Mn | ≤ 2.00 | ≤ 1.20 |
| Si | ≤ 1.00 | ≤ 0.80 |
| P | ≤ 0.030 | ≤ 0.035 |
| S | ≤ 0.020 | ≤ 0.020 |
| Cr | 21.0–23.0 | 24.0–26.0 |
| Ni | 4.5–6.5 | 6.0–8.0 |
| Mo | 2.5–3.5 | 3.0–5.0 |
| N | 0.08–0.20 | 0.24–0.32 |
| Composition: standard | UNS S31803 (A240, A182 F51, A790) | A240/A182 F53 (S32750) |
| Mechanical properties (minimum) | ||
| Yield strength | – | – |
| Tensile strength | – | – |
| Elongation | – | – |
| Hardness | – | – |
| Properties: condition | A182 F51 (S31803), solution annealed | A182 F53, solution annealed, ≤ 50 mm |
| Use and supply | ||
| PREN (minimum – typical) | 31 – 34 | 38 – 43 |
| Density | 7.8 g/cm³ | 7.8 g/cm³ |
| Service temperature | – | – |
| Standards by product form | Plate, coil, strip: A240 / SA-240 Bar and section: A276; A479 / SA-479 Forging and flange: A182 / SA-182 HIP part (powder metallurgy): A988 / SA-988 Seamless and welded pipe (piping): A790 / SA-790 | Forging and flange (B16.5): A182 / SA-182 Bar: A479 / SA-479; A276 Plate, coil, strip: A240 / SA-240 Seamless pipe (line): A790 / SA-790 Heat exchanger tube: A789 / SA-789 |
| Typical applications | Offshore oil and gas Chemicals and petrochemicals Pulp and paper Chemical tankers | Offshore oil and gas Subsea Desalination (SWRO) Chemicals and pulp |
Composition and minimum properties per the standard listed on each datasheet; PREN uses the minimum and the middle of the ranges. For the actual value, use the heat certificate.
Most searched comparisons
- 316 / 316L stainless x 317L stainless steel
- Duplex 2205 (F51 / S31803) x Duplex S32205 / F60
- Inconel 625 / Alloy 625 x Incoloy 825
- 17-4PH stainless steel – UNS S17400 (ASTM A564 Type 630) x 15-5PH – UNS S15500 (XM-12)
- SAE 4140 x SAE 4340
For pitting resistance, see the PREN calculator; for steel weldability, the carbon equivalent; to choose by medium, steel by corrosive medium.
Frequently asked questions
Can I replace 2205 with 2507?
Yes, 2507 works wherever 2205 works in corrosion and strength. The opposite does not hold for seawater or hot chlorides.
Do both have the same temperature limit?
Yes. The ASME code limits both to 316 °C (600 °F). In long exposure above ~250–280 °C there is a risk of 475 °C embrittlement (hardening of the ferrite); check the limit in the design code.
What care is needed when welding 2507?
Control heat input and interpass temperature to keep the ferrite–austenite balance, and use a super duplex filler metal (ER2594).